HomeElectronicsAccessories & SuppliesAudio & Video AccessoriesTV Accessories & PartsCA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance
product_image_name-Generic-CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance-1product_image_name-Generic-CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance-2product_image_name-Generic-CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance-3product_image_name-Generic-CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance-4product_image_name-Generic-CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance-5

Share this product

Shipped from abroad

CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance

KSh 2,029
KSh 2,84429%

In stock

+ shipping from KSh 232 to CBD - UON/Globe/Koja/River Road
0 out of 5
(No ratings available)
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees KSh 232
Ready for pickup between 02 June and 04 June if you place your order within the next 2hrs 26mins

Door Delivery

Delivery Fees KSh 342
Ready for delivery between 02 June and 04 June if you place your order within the next 2hrs 26mins

Return Policy

Easy Return, Quick Refund.Details

Seller Information

Niduo

New Seller

Be the first to follow

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details


CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance
  • I am an international seller
Our shop sells the most popular 3C consumer electronics products,such as mobile phone accessories,computer accessories,game peripherals,smart wearables,and follow the most popular fashion trends. If you like our products,please follow us,become our follower and fan.We will provide you with the most popular products to satisfy your fashion shopping experience.Package : SMDis_customized : YesModel Number : CA-888 15-24 inch Universal LCD Display Power Board Power ModuleApplication : ComputerCondition : NewType : Voltage RegulatorBrand Name : ZiqqucuOrigin : Mainland China
CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV MaintenanceProduct selling point:
1. Using high-quality materials, the quality is guaranteed
2. Easy to use, good stability
3. Small and exquisite size
4. Beautiful appearance
5. Wide applicationuse:
The damage to the power board of the LCD display occupies a large proportion. Among them, power driver chips, high-power power switch tubes, sampling resistors, etc. are the most common damages. Due to the variety and variety of these components, they often cannot be repaired due to the lack of the same spare parts.
The LCD universal power supply module has the advantages of simple wiring, convenient installation, saving time, and improving the success rate of maintenance.Pin Definition:
Pin 1: DRAIN, power control terminal, connected to the D pole of the high-power MOS power tube. Usually the middle foot of the power switch tube
2 feet: GND, module ground wire 300v, connected to the negative pole of the capacitor, it can be on the same line. Directly connect the negative pole of the large filter capacitor
Pin 3: VCC, module power supply terminal, connected to the positive pole of the capacitor after rectification at the feedback winding terminal, continuous power supply, the voltage is between 12-18V.
Pin 4: FB, voltage regulator feedback, connect to pin 4 of the optocoupler, please confirm that pin 3 of the optocoupler is connected to the hot ground. If it is not the hot ground, short the optocoupler to the hot ground, and disconnect the peripheral circuit of pin 4.
5 feet: start start foot, connect the positive pole of +300v capacitor
Please be sure to take a good look at the specific connection method before modifying it, and do not blindly connect it. If you don't understand it, please check the circuit diagram below several times!How to use:
1. Remove the power chip (usually 8 pins) on the board, and the switch tube (mos tube)
2. Check the 300v capacitor and whether there is any bulge on the appearance of the capacitor at the load end. If there is any problem, replace it first.
3. Check whether there is a short circuit at the load end, AD board, high voltage board, etc.
4. Connect the corresponding circuit of the module, and carefully check that there is no wrong connection, if the wrong connection will cause the module to burst
5. Install in the radiator position, pay attention to insulation, do not short-circuit
6. Power on, measure whether the voltage is output, if there is no output, check the reasonPrecautions:
1. Before using this module, please check whether there is a short circuit at the cold end. If there is a short circuit, repair it first. If the capacitor is bulged, please replace it first. If the high-voltage package circuit is short-circuited, disconnect it first. Before this module is installed, remove it. The power chip and mos tube of the module, at this time, the voltage of the electrode in the middle of the switch tube to the hot ground should have a voltage of about 300v.
2. If the 3-pin of the optocoupler is not connected to the hot ground, please connect the 3-pin to the hot-ground, and at the same time remove the peripheral circuit of the 4-pin, and connect the white wire to the 4-pin position.troubleshooting:
1. No output: the wiring is wrong, it cannot be wrongly connected or missed, this will only burn the chip, make sure there is no short circuit at the load end, is there any problem with the optocoupler
2. The control of the optocoupler part is wrong. The 1st pin of the optocoupler is not grounded, and the 2nd pin is connected to the vcc part through a resistor.
3. The heat is serious. If the tube is used for less than 10 minutes, except for the cause of the heavy load, check the diode and capacitor on the hot-end transformer for damage.
4. The voltage is unstable and jumps: the load is too light or too heavy, the continuous jump of the voltage means that the load is too light, and the hiccup is too heavy. Generally, there may be slight voltage jumps when the load is not connected, mainly due to the different design of the transformer. , you can try to connect the load, or connect a 100 ohm resistor at the 5v end to testPackage Included:
Module*1image


image


image


image


image


image


image


image

Specifications

Key Features

Package : SMDis_customized : YesModel Number : CA-888 15-24 inch Universal LCD Display Power Board Power ModuleApplication : ComputerCondition : NewType : Voltage RegulatorBrand Name : ZiqqucuOrigin : Mainland China
CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV MaintenanceProduct selling point:
1. Using high-quality materials, the quality is guaranteed
2. Easy to use, good stability
3. Small and exquisite size
4. Beautiful appearance
5. Wide applicationuse:
The damage to the power board of the LCD display occupies a large proportion. Among them, power driver chips, high-power power switch tubes, sampling resistors, etc. are the most common damages. Due to the variety and variety of these components, they often cannot be repaired due to the lack of the same spare parts.
The LCD universal power supply module has the advantages of simple wiring, convenient installation, saving time, and improving the success rate of maintenance.Pin Definition:
Pin 1: DRAIN, power control terminal, connected to the D pole of the high-power MOS power tube. Usually the middle foot of the power switch tube
2 feet: GND, module ground wire 300v, connected to the negative pole of the capacitor, it can be on the same line. Directly connect the negative pole of the large filter capacitor
Pin 3: VCC, module power supply terminal, connected to the positive pole of the capacitor after rectification at the feedback winding terminal, continuous power supply, the voltage is between 12-18V.
Pin 4: FB, voltage regulator feedback, connect to pin 4 of the optocoupler, please confirm that pin 3 of the optocoupler is connected to the hot ground. If it is not the hot ground, short the optocoupler to the hot ground, and disconnect the peripheral circuit of pin 4.
5 feet: start start foot, connect the positive pole of +300v capacitor
Please be sure to take a good look at the specific connection method before modifying it, and do not blindly connect it. If you don't understand it, please check the circuit diagram below several times!How to use:
1. Remove the power chip (usually 8 pins) on the board, and the switch tube (mos tube)
2. Check the 300v capacitor and whether there is any bulge on the appearance of the capacitor at the load end. If there is any problem, replace it first.
3. Check whether there is a short circuit at the load end, AD board, high voltage board, etc.
4. Connect the corresponding circuit of the module, and carefully check that there is no wrong connection, if the wrong connection will cause the module to burst
5. Install in the radiator position, pay attention to insulation, do not short-circuit
6. Power on, measure whether the voltage is output, if there is no output, check the reasonPrecautions:
1. Before using this module, please check whether there is a short circuit at the cold end. If there is a short circuit, repair it first. If the capacitor is bulged, please replace it first. If the high-voltage package circuit is short-circuited, disconnect it first. Before this module is installed, remove it. The power chip and mos tube of the module, at this time, the voltage of the electrode in the middle of the switch tube to the hot ground should have a voltage of about 300v.
2. If the 3-pin of the optocoupler is not connected to the hot ground, please connect the 3-pin to the hot-ground, and at the same time remove the peripheral circuit of the 4-pin, and connect the white wire to the 4-pin position.troubleshooting:
1. No output: the wiring is wrong, it cannot be wrongly connected or missed, this will only burn the chip, make sure there is no short circuit at the load end, is there any problem with the optocoupler
2. The control of the optocoupler part is wrong. The 1st pin of the optocoupler is not grounded, and the 2nd pin is connected to the vcc part through a resistor.
3. The heat is serious. If the tube is used for less than 10 minutes, except for the cause of the heavy load, check the diode and capacitor on the hot-end transformer for damage.
4. The voltage is unstable and jumps: the load is too light or too heavy, the continuous jump of the voltage means that the load is too light, and the hiccup is too heavy. Generally, there may be slight voltage jumps when the load is not connected, mainly due to the different design of the transformer. , you can try to connect the load, or connect a 100 ohm resistor at the 5v end to testPackage Included:
Module*1

What’s in the box

1x packages

Specifications

  • SKU: GE840EA4BDPLNNAFAMZ
  • Model: SM-DSWDQ-9-21-6334
  • Production Country: China
  • Size (L x W x H cm): 20x10x20
  • Weight (kg): 0.4
  • Main Material: other

Customer Feedback

This product has no ratings yet.

CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance

CA-888 15-24 inch Universal LCD Display Power Supply Board Module Switch Tube DM0465R DM0565R for LCD Display TV Maintenance

KSh 2,029
KSh 2,84429%
Questions about this product?

Recently Viewed

See All