Features:
Specifications:
Voltage: 6V~30V(support micro USB 5.0V)
Quiescent Current: 20mA
Operating Current: 50mA
Operating Temperature: -40℃~85℃
Size: Approx. 6.2*3.8*1.7cm / 2.44*1.49*0.67"
Timing Range: 0.1seconds to 999 minutes(continuously adjustable)
Instruction:
Operation Mode:
P1: After triggering signal, switch is
connected for "OP" time, then disconnected; within the "OP" time:
P1.1: if trigger signal again, it is
invalid.
P1.2: if trigger signal again, restart timing.
P1.3: if trigger signal again, switch is disconnected, stop timing.
P-2: After triggering
signal, switch is disconnected for "CL" time, then switch is connected for "OP" time, and disconnect after timing.
P3.1: After triggering signal, switch is connected
for "OP" time, then switch is disconnected for "CL" time, and enter loop. If
trigger signal during loop, switch is disconnected and stop timing. The loop times
(LOP) can be set.
P3.2: After power on, no need trigger
signal, switch will be connected for "OP" time, then disconnected for "CL" time, and enter loop. The loop times (LOP) can be set
P-4: Signal holding function. If there is trigger
signal, timing will be reset, switch remains connected; when the signal
disappears, it will disconnect after "OP" time. During timing, if there is a
signal, timing will be reset.
OP: Connect time. CL: Disconnect time. LOP:
Loop times(1~999, "---" indicates infinite times)
All above parameters are independent from
each other, but all modes use the same parameters. For example, if set OP time
as 5 seconds in P1.1, then change to P1.2, then the OP time in P1.2 will also be
5 seconds.
Press SET button at the main interface (display
000), it will show OP(CL, LOP) and corresponding time.
If there is only OP mode (e.g. P1.1, P1.2, P1.3), press SET button to
display OP and corresponding time only.
If there are OP, CL, LOP modes (e.g.P3.1,
P3.2), press SET button to display OP, CL, LOP and corresponding time.
After setting mode, press SET button at the
main interface to check the parameter of present mode.
How to Choose Timing Range:
After setting parameter in the interface selection
mode, press the STOP button to select the time range:
XXX. If the last decimal
point lights up, the time range is 1sec to 999sec.
XX.X If the second last
decimal point lights up, the time range is 0.1sec to 99.9sec.
X.X.X. If all decimal points
light up, the time range is is 1 min to 999 min.
For example, if you set OP as 3.2 seconds,
the make the second last point light up, and it displays 03.2
How to Set Parameter:
1. Make sure operation mode.
2. According to the operation mode, at main
interface(after power on, it will flash present mode then enter main interface),
press and hold SET button for 2 seconds to enter mode selection interface, then
press UP, DOWN button to choose mode (P1.1~P-4)
3. After selecting mode, press short SET button
to set the corresponding parameter, then the parameter you want to set will
flash. Press UP, DOWN button to set value, then press STOP button to select
time range. Press SET button to set next parameter.
4. After setting mode parameter, press and
hold the SET button for 2 seconds then the present mode will flash, and go back
to the main interface.
Main interface: when relay does not work,
it shows "000" (no decimal point); when relay is working, it shows decimal
point
Mode Selection Interface: Press and hold SET
button to enter. After setting, press and hold SET button to back to main
interface.
Relay Enable Mode:
1. NO: Connection is allowed during OP time.
2. OFF: Connection is not allowed, always turned
off.
Press STOP button at main interface to
change between ON and OFF, the present state will flash then back to main
interface. (This is emergency stop function, used to disconnect relay.)
Sleep Mode:
C-P sleep mode: if no operation within 5
minutes; display will close automatically while procedure runs normally.
O-d normal mode: displays always shows.
Press and hold STOP button for 2 seconds to
change between C-P and O-d, present state will flash and then back to the main
interface.
Package Includes:
1 x Timer Switch Module
This product has no ratings yet.