Portable Pen Type PH Meter ATC Water Quality Test Digital Acidity Alkalinity PH Meter Tester for Aquarium Pool Water Laboratory
- I am an international seller
Our shop sells the most popular 3C consumer electronics products,such as mobile phone accessories,computer accessories,game peripherals,smart wearables,and follow the most popular fashion trends. If you like our products,please follow us,become our follower and fan.We will provide you with the most popular products to satisfy your fashion shopping experience.pH Sensor Electrode Probe pH meter Replacement for pH tester pH818 pH828 ph838
USD 22.97/piece
SMART SENSOR Digital Dissolved Oxygen Detector Meter Portable Dissolved Oxygen Water Quality Tester Dissolved Oxygen Analyzer
USD 248.14/piece
2 in 1 TDS/Temp Tester 0-9990 ppm TDS Meter Water Quality Monitor Purity Analyser Automatic Calibration for Pool Aquariums
USD 4.76/piece
Feature
This is an economic type ph meter with high precision,digital readout, large LCD display screen,
Very convenient to test ph value for lab and industry and other
aspects, because of the cabinet appearance and light weight.
1. High-accuracy
2. resolution:0.1 pH
3. PH meter range: 0.0 to 14.0 pH
4. Accuracy: ±0.1pH
5 .Calibration: Manual, 1 point,
6. Operating Conditions: 0 to 50°C (32 to 122F) RH max 95%
7. Battery Type:4 x 1.5V alkaline
8. Battery Life :Approx.150 hours of use
9. Dimensions:152 x 30 x 21 mm(5.9 x 1.2 x 0.8")
10. Weight:53 g
OPERATION
1. Remove the protective cap. Do not be alarmed if white crystals appear around the cap. This is normal with pH electrodes and they dissolve when rinsed with water.
2. Turn the meter on sliding the switch on the top
3. Immerse into solution up to the max immersion level.
4. Stir gently and wait until the display stabilizes. Readings are automatically compensated for temperature variations.
5. After use, switch off pH meter, use the water clean the electrode and replace the protective cap.
CALIBRATION
? Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution
? Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.9.
Calibration is now complete.
ALWAYS USE FRESH BUFFERS FOR CALIBRATION.
BATTERY REPLACEMENT
When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual.
ELECTRODE REPLACEMENT
1.Remove the protective cap.
2.Unscrew the plastic ring on the top of the electrode .
3.Pull out the electrode and replace it with a new one. make sure the gaskets are in place before screwing back the ring.