1. A variety of fields perfect use, convenient operation and practical settings, is your side temperature control housekeeper.
2. It is precise and reliable with good long‑term stability. Convenient for install and fixed. Small size, low power consumption, fast response.
3. Easy operation, to set start temperature, stop temperature, corrected temperature connector and so on.
4. Suitable for hatching, breeding, air and water temperature control and other related temperature detection and control.
5.
Specifications:s are optional, precise temperature control, temperature calibration.
Specifications::
ItemType: Digital Temperature Controller
Material: Plastic
Weight: Approx. 51g / 1.8oz
Operating Voltage
Specifications:s: 12V, 24V, 110-220V
Accuracy Level: 0.1
Temperature Measurement Range: -50-110 (℃)
Temperature Measurement Accuracy: -15-65 (℃)
Humidity Measurement Accuracy: 1 (RH)
Temperature Measurement Error: ±1 (℃)
Applicable Environment: -15-55℃ / 20%-85%RH
Product Embedded Hole Size: 73mm / 2.9in, Hole Diameter (φ4mm)
How to use:
1. Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required starting temperature through the up and down buttons.
2. Press the setting key once to enter the internal menu, the display is P0, switch to P1 through the up and down keys, press the setting key again, and set the required stop temperature through the up and down keys.
3. Enter the internal menu in the same way, switch to P2 through the up and down buttons, press the setting button again, and set the required calibration temperature through the up and down buttons. (Note: In the setting, if the detected temperature value is 0.5°C larger than the actual temperature value, then the calibration temperature that needs to be set is -0.5°C. If the detected value is 1°C lower than the actual temperature value, the calibration temperature that needs to be set is 1°C. Detection temperature + Correction temperature = Actual temperature.)
4. Enter the internal menu in the same way, switch to P3 by pressing the up and down buttons, press the setting button again, and set the required delay time through the up and down buttons in minutes. (Note: Delayed start is generally used for compressor refrigeration. If it is used for refrigerators and freezers, this value needs to be set. According to the compressor back pressure, the general setting value is 3-6 minutes. If you are not used for control or no delay function is needed, just skip it.
Temperature control mode
1. Setting essentials:
Start temperature stop temperature.
2. Press the setting key to enter the internal menu, select P0 to start the temperature change and set the P0 value to 30°C.
3. Press the setting key to enter the internal menu, select P1 to stop the temperature and set the value of P1 to 26℃..
Package list:
1 x
Temperature Controller
Note:
1. Press and hold the up and down keys at the same time, wait until the screen displays 888 to restore the factory settings.2. The screen displays LLL, indicating that the temperature probe is not plugged in, disconnected, or damaged, just replace it.3. The screen display HHH indicates that the temperature probe is short‑circuited and exceeds the temperature detection range.