product_image_name-Generic-KZ35 35W Constant Current Electronic Load USB Type C QC2.0/3.0 AFC FCP Triggers-1

Share this product

Shipped from abroad

KZ35 35W Constant Current Electronic Load USB Type C QC2.0/3.0 AFC FCP Triggers

KSh 4,090
KSh 7,05142%

In stock

+ shipping from KSh 355 to CBD - UON/Globe/Koja/River Road

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees KSh 355
Ready for pickup between 06 June & 10 June when you order within next 3hrs 52mins

Door Delivery

Delivery Fees KSh 465
Ready for delivery between 06 June & 10 June when you order within next 3hrs 52mins

Return Policy

Easy Return, Quick Refund.Details

Seller Information

Noarlall

40%Seller Score

3 Followers

Follow

Seller Performance

Order Fulfillment Rate: Excellent

Quality Score: Very Poor

Customer Rating: Very Poor

Product details

This product can be used as ordinary electronic load, can also do USB electronic load use, can trick support QC2.0/QC3.0/AFC/FCP Fast charge protocol, trigger output 5v/9v/12v/20v and other voltages, the use of liquid crystal display, friendly human-computer interface and excellent performance indicators, Meet a wide range of testing needs.

Product Technical Parameter

Product model

KZ25

KZ35

Rated operational voltage

DC4.0-25.0V(Reverse Solution Protection)

Max discharging power

25W

35W

Rated operational current

0.03-4.00A(0.22A tuning when Fan starts)

0.03-5.00A(0.22A tuning when Fan starts)

Fan speed

Oil bearing intelligent

temperature control fan5800±10%RPM

Hydraulic bearing intelligent

temperature control fan. 8000±10%RPM

Quick charge trigger mode

QC2.0 5V,9V,12V,20V,QC3.0,AFC9V ,FCP

Constant current accuracy

±(1%+3 digits)

Voltage accuracy

±(0.5%+3 digits)

Heat dispatch method

Intelligent temperature control fan + All aluminum fan

Working temperature

-20℃-40℃

Expansion port

Micro USB port,Type-C port

Overvoltage Protection(OVP)

Default 25.2V (can be set by yours)

Overcurrent protection(OCP)

Default 4.10A (can be set by yours)

Default 5.10A (can be set by yours)

Over-power protection(OPP)

Default 25.5W (can be set by yours)

Default 35.5W (can be set by yours)

Undervoltage Protection(LVP)

Default 4.0V (can be set by yours)

Over-temperature protection(OTP)

Default 80℃ around (not set)

Product weight

About 66g

Product size

101*45*26mm

Application

Recommended selection of Factory batch AgingKZ35

Package include:

1pcs KZ35 Constant Current Electronic Load

image

A. External wiring port, can be used for s-welding terminals

B. Type-c port: Maximum Current 5 A, can trigger quick charge (this product does not support PD trigger)

C. USB male port: Maximum current 5 A, can trigger quick charge

D. Micro USB port:Maximum current 2 A, can not trigger fast charge

E. All-aluminum black heatsink and intelligent temperature-controlled fan

F. Trigger on (TRG) (short pre enter trigger mode selection interface, long pre can test charger support that fast charge mode)

G. ON/OFFon (short pre ON/OFF load, long pre lock load current, prevent misoperation)

H. En potentiometer keys (two operation way, long pre and short pre, have different function atdifferent mode)

I. LCD display

J. Specification QR code, sweep code can view the latest instructions

Load Features:

1.The current A voltage V power W capacity Ah and discharge time can be displayed;

2.Have a sound protection mechanism;

3.Automatic statistics of discharge capacity and discharge time;

4.Set maximum discharge Capacity (OAH) and maximum discharge time (OHP);(To achieve unattended power aging testing)

5.Intelligent temperature-controlled fan, when the power is greater than 10W or the temperature is greater than 40 ℃ fan starts automatically;

6. With a rotary coded potentiometer, the current can be precisely adjusted to an accurate 0.01A,The current can be locked to prevent misoperation;

7. You can set the load to manually or automatically return to normal work after the release of the protection mechanism (REC)

8.Data group function: You can choose whether to add up the capacity value and running time of the previous stage;

Load function Detail

First, perfect protection mechanism

1. Load voltage has anti-reverse protection, reverse connection does not burn;

2. OVP Overvoltage Protection (default 25.2V, can be set its, after Overvoltage protection, LCD interface flashing display OVP);

3. OCP Overcurrent Protection (default 4.10A/5.10A, can be set its, after overcurrent protection, LCD flashing display OCP);

4. OOver power protection (default 25.5W/35.5W, can be set its, after power protection, LCD flashing display OPP);

5. OTP Over-temperature protection (after the load temperature is greater than 80 ℃, over-temperature protection, liquid crystal flicker display OTP);

6.PUndervoltage Protection (default 4.0V, can be set its, after Undervoltage protection LCD flashing displayP, In applications such as battery discharge testing, the setting of suitableP can effectively prevent the battery from transitioning to discharge, so as not to damage the battery ).

Second, the electronic load on the initial state of power:

The electronic load automatically saves the switching state before shutting down and acts as the initial state of the power-on;

Third, discharge capacity and discharge time statistics:

1. Discharge capacity statistics: Starting from the open load statistics, until the load disconnect thought to complete a discharge proce, statistical end;

2. Discharge time Statistics: Starting from the open load statistics, until the load disconnect thought to complete a discharge proce, statistical end;

Four, set the maximum capacity (OAH) and set the maximum discharge time (OHP):

1. Set maximum Capacity (OAH): When the OAH function is started, when the load discharge capacity is higher than the maximum capacity set, the electronic load stops automatically and flashes to display "OAH", and when the OAH alarm is lifted, the capacity statistics are automatically emptied;

2. Set the maximum discharge time (OHP): When the OHP function is started, when the load running time is greater than the maximum discharge time set, the electronic load stops automatically and flashes to display "OHP", and when OHP alarm is lifted, the time statistics are automatically emptied;

Note: When the OAP and OHP functions are not turned on, the electronic load will record the discharge capacity and discharge time,When the OAHand OHP functions are turned on, the electronic load stops working after the set value;When the OHP function is turned on, the running time of the electronic load is the countdown mode;

OAP and OHP functions, can be a good implementation of unattended power aging testing.

V. Data set Features:

Divided into "DAT0", "DAT1"

DAT0: Flashing only shows the capacity value and running time of the previous stage, and does not add up to the stage;

DAT1: Flashing shows the capacity value and running time of the previous stage, and automatically accumulates to the stage;

Vi. set the load to manually or automatically return to normal operation after the release of the protection mechanism (REC function)

Set the REC:ON state, the load automatically returns to normal work after the contact protection mechanism, and the REC:OFF state, the load needs to be manually returned to normal work after the release of the protection mechanism.

Seven, set power on whether to automatically trigger the fast charge function (AUTO function)

Set the AUTO:ON, power on the automatic trigger fast charge, suitable for batch test aging charger;AUTO:OFF, power on does not trigger fast charge.

Load function Interface Operation Description:

First, the operation interface operation instructions:

1. The electronic load is powered on and then enters the operating interface, which is used to turn the electronic load on or off by short preing the "ON/OFF" on, and to modify the current of the electronic load in real time by rotating the encoder potentiometer;

2. Short pre the en potentiometer key to toggle the downlink display content (current/power/capacity/time);

3. In any display interface, the rotating en potentiometer will automatically switch to the current display interface;

4. In the current display interface , the long pre "ON/OFF" on is used to turn the data lock function on or off, if the data lock function is turned on, the locking symbol " -- " will be displayed in front of the current, at this time can not adjust the load current in real time by rotating the en potentiometer to prevent misoperation;

5. In the Capacity/Time interface, Long pre the "ON/OFF" on to empty the correspondingcapacity/time data

image

Second, the Setup interface operation instructions:

1. In the running interface, the long pre en potentiometer enters the setup interface;

2. By rotating the encoder potentiometer, adjust the size of the parameters, increase clockwise, and decrease counterclockwise; switch the parameters that need to be modified by short preing the rotary encoder;

3. In the maximum capacity (OAH)/Maximum discharge time (OHP) interface, short pre "On/off" on to select the corresponding function of the turn on or off, if closed, the display "----";

4. In the maximum capacity (OAH) interface, Long pre the "ON/OFF" on to select the capacity range (9.999Ah/99.99 Ah /999.9 Ah /9999 Ah);

5. Parameter settings complete, long pre encoder potentiometer, exit the Setup interface, set parameters automatically saved;

image

Trigger/Trick function

1.Trigger function:

The charger can be QC2.0, QC3.0, Samsung AFC 9V, Huawei FCP, a variety of mode for decoy trigger.

2.Fast charge Support automatic detection function:

Long pre the trigger on TRG can detect the charger's support for the fast charge mode.

3.Power-on Auto trigger fast charge function:

Power-on automatic trigger fast charge (set in AUTO:ON state), suitable for batch testing aging charger when used.

image

First, the trigger/Decoy function Description:

The trigger/Decoy feature is the ability to send a signal on the D+ D- to induce the charger to charge quickly, and the load shuts down automatically after entering this mode. Trigger/Return to the switch state before the load when the trigger is complete. (with the exception of automatic detection, other modes send only trigger instructions and do not determine whether succe is triggered)

Second, the trigger/Decoy function Interface Operation Description:

1. First determine which kind of fast charge the charger supports;

If you are unsure, you can detect the support of the charger for the fast charge mode by preing the TRG trigger on.

After the long pre trigger on TRG, the liquid crystal downlink flashes dynamically to show ' 2. ' 3. ' A. ' F ', in the flashing proce is the corresponding QC2.0,Q C3.0,AFC,FCP Fast Charge protocol detection, After the detection is completed, the charger supports the protocol will show ' 2.3.A.F ' on the LCD downlink, which supports which corresponds to which the corresponding display; short pre the En potentiometer on back to the load interface; 2. After determining the fast charge protocol supported by the charger, short pre the trigger on TRG, enter the trigger Protocol selection interface (if you do not want to trigger the fast charge, you can short pre the trigger on TRG return to the Load interface), By rotating the en potentiometer, select the Protocol (QC2.0,QC3.0,AFC,FCP) to be triggered, After selecting short Pre en potentiometer on, enter the trigger of the protocol, the liquid crystal will dynamically display "----", after the trigger is completed, the corresponding display voltage will be as follows:

QC2.0 mode:

The LCD downlink will show '-05.0 ', which can be selected by rotating the en potentiometer to '-09.0 ', '-12.0 ', '-20.0 ', Representing the 5.0v,9.0v,12.0v,20.0v of the QC2.0 protocol, the LCD uplink will display the real-time voltage, select the voltage file to be triggered and then short pre the Rotary Encoder on, back to the load interface;

QC3.0 mode:

LCD downlink will show '-05.0 ', can be rotated en potentiometer to increase or decrease 0.2V, LCD uplink will display real-time voltage, select the voltage file to be triggered after short pre the Rotary Encoder on, back to the load interface;

AFC/FCPmode:

When the trigger is complete, it will automatically return to the load interface

image

image

Q&A

Q:My charger nominal maximum support QC2.0 12V2A How do I test if the charger is supported?

A:Insert the load, short pre the trigger on TRG, enter the fast charge protocol selection interface, through the rotary en point selection QC2.0 mode, short pre the en potentiometer, the liquid crystal will dynamically display "----", activate QC2.0 fast charge mode, LCD downlink display '-5.0 ', by rotating the en potentiometer, select '- 12.0 ' file, LCD uplink will show the actual voltage, see if the actual voltage is around 12.0V, and then short pre the En potentiometer on, back to the load interface; Open the load, slowly adjust the current to 2 A, see if the voltage has a significant drop (>0.5V), then let the load work for a period of time, and measure the heat of the charging head. If the load restarts or the voltage drops significantly and the charging head heats up sharply, it means that the charging head load capacity is not sufficient and must be used in a reduced amount.

Q:Is my PD2.0 charger supported?

A:The load can age the PD charger, but PD seduction is not poible. The two-headed type-c line connects the PD charger and the load, and the PD charger outputs 5V by default. If the PD charger supports QC2.0 at the same time, high preure aging can be achieved by luring QC2.0.

Q:I want to release fast charge how to achieve?

A:Method 1: In the load interface, long pre the trigger on TRG to detect the charger on the fast charge mode support situation, after the test is completed short pre the En potentiometer on, back to the load interface, then the original selected fast charge mode will be released; Method 2: Long Pre the En potentiometer on into the Setup interface, select the ' AUTO:OFF ' state, and then put the load back on the power, the original selected fast charge mode will also be released.

Application Scenarios

Can do ordinary load use, do power aging test, battery discharge test, etc.

Auxiliary measurement of the quality of Micro USB charging cable

Auxiliary measurement of the quality of type-c charging lines

Auxiliary measurement charger Output current capability

Charger Factory Batch Aging test use

About shipping
Shipping and Packaging All itwill be double checked and well packed before sending.Itwill be dispatched within 2 business days after buyers pay for the order. It usually takes about 14 to 18 working days for delivering the package to the destination(for e areas,it may take a little longer). 

Special Announcement:
Please fill in the correct and detailed consignee, address and phone number in the order. For fast and correct delivery.If you do not receive order within 30 working days,please feel free to contact Customer Service before leaving Negative and Neutral Feedback, we will do our best to help you resolve the problem.TaxNo, you will only pay what is quoted as total cost at checkout, no more. You are not expected to pay any additional duties ores. If you are asked by Customs or our logistic partner to pay duties, please contact our Customer Service .

Your 100% satisfaction is very important to us
If the product is not on good condition, You can return this product within 14 working days, please contact customer service center before returning.FeedbackYour satisfaction is our first priorityIf you receive the order and it is in good condition,we would be grateful if you would leave us 5 star Positive Feedback for the transaction.

Specifications

Key Features

  • Model Number:KZ35
  • Type:Electronic Device Battery Tester
  • DIY Supplies:ELECTRICAL

What’s in the box

1X KZ35 35W Constant Current Electronic Load USB Type C QC2.0/3.0 AFC FCP triggers Battery Testser Discharge Capacity monitor

Specifications

  • SKU: GE840IP27SAD2NAFAMZ
  • Model: NOAdianchiceshiyi2463
  • Size (L x W x H cm): 10*10*10
  • Weight (kg): 0.2
  • Main Material: PVC
  • Care Label: NA
  • Shop Type: Jumia Mall

Customer Feedback

This product has no ratings yet.

KZ35 35W Constant Current Electronic Load USB Type C QC2.0/3.0 AFC FCP Triggers

KZ35 35W Constant Current Electronic Load USB Type C QC2.0/3.0 AFC FCP Triggers

KSh 4,090
KSh 7,05142%
Questions about this product?

Recently Viewed

See All